| Low Range (0-4%, 0-10%, 0-20%)
Mid Range (0 to Inversion)
Full Range (0-100%)
High Range (80-100%)
Flow-Through Analyzers in 1" to 4" Pipe Sizes
Insertion Analyzers for Installation in Pipes 6" and Up
Three Styles of Flow-Through Configurations
________________________________________
· CSA & FM Certifications Available
· CE & EEX Certifications Available
· Temperature Probe Included
· Self Calibrating Current Loop
· Configurable Current Loop & Alarm Outputs · Net Oil and Net Water (with pulse input from flow meter)
· MODBUS· RTU, HART· Available
· 24 VDC, 120 VAC and 230 VAC
· Self-checking Electronics
This family of Water Cut Analyzers was developed specifically for use in the oil industry. The Low Range Analyzer is typically used for custody transfer or pipelines. The Full Range is used for emulsion control in tanks, for control of high water cut situations, and for interface control. Flexibility for the user is provided for through various configurations including an insertion unit.
Phase Dynamics' Full and Low Range Analyzers offer the most accurate measurement possible. Many major oil companies have used the Low Range Analyzer on custody transfer pipeline installations. Phase Dynamics utilizes the unique, patented, "Oscillator Load Pull" microwave technology, which provides for this outstanding capability.
All functions of the analyzers are accessed through the front panel by four push button switches. The LCD display indicates the measurement value as well as temperature, net oil, net water, and phase of the emulsion (full range only). Full digital access to the information is standard. Electronics are available in NEMA-4 or explosion proof enclosures.
Water Cut Analyzer Operational Specifications:
PARAMETER LOW RANGE MID RANGE FULL RANGE HIGH RANGE
RANGE 0-4% & 0-10% 0-20% 0-Inversion 0-100% 80-100%
ACCURACY +/- 0.04% (0-4%) +/-0.1% (4-10%) +/-0.2%
Oil Phase Only +/-0.5%
Oil Phase Only Oil Phase +/-0.5%
Water Phase +/-1.0% +/-0.6%
Water PhaseOnly
REPEATABILITY +/-0.02% +/-0.1% +/-0.1% Oil Phase +/-0.1%
Water Phase +/-0.5% Water Phase +/-0.3%
RESOLUTION 0.01% 0.10% 0.10% 0.10% 0.10%
FLUID TEMPERATURE 60-160oF 60-160oF 60-160oF 60-160oF 60-160oF
HIGH TEMPERATURE VERSION 60-220oF 60-220oF 100-600oF 100-600oF 100-600oF
SALINITY Not Applicable Not Applicable Not Applicable 0.5%-8% Water
Oil Not a Factor 0.5%-8%
Water All percentages are expressed as absolute water content percentages
System Specifications
General Power Requirements:
·100 - 130 VAC 60 Hz (50 Hz optional)
·200 - 260 VAC 50-60 Hz (optional)
·18-28 VDC (optional)
·25 Watts Typical, 50 Watts Maximum
Outputs:
·Analog: Field Selectable 0-20mA or 4-20ma, 12 bit D-to-A Conversion
·Digital: RS-422 Standard, RS-485 (Optional), MODBUS· RTU (Optional), HART· (Optional)
Alarm and System Error Relays:
·Alarm Dry Contact Closure Rated 1 Amp, 120 VAC, Field Definable Set point, NO or NC with Time Delay
·System Error Dry Contact Closure Rated 1 Amp, 120 VAC
Flowmeter Inputs:
·Voltage or Magnetic Pickup Pulse (3mV to 15V max.) With Field Selectable Definition
·Current Input 0-20 or 4-20mA with Field Selectable Definition
Fluid Temperature Compensation:
·Automatic with Built-in RTD Temperature Probe
Ambient Temperature Ranges:
·Measurement Section: -40o to =120oF
·Electronics: =32o to +120oF; Sun Shade Recommended
Fluid Temperatures:
·Standard 60o to 160oF
·Optional 60o to 220oF
·Optional 100o to 400oF
·Optional 100o to 600oF
·Lower Temperatures Optional
Certifications:
·CSA, FM, CE & EEx (Optional) System Electronics Enclosures
Standard Explosion Proof Enclosure:
·17.4 H x 14.0 W x 9.9 D inches; 59 lbs., NEMA 4,7 & 9; Class 1, Div. 1, Groups C&D; EEx d HB T5 89oC - IP66 (Optional); See Figure 1
Rain and Dust Tight Fiberglass Enclosure:
·16.3 H x 10.5 W x 7.9 D inches; 17 lbs., NEMA 4; See Figure 2
Measurement Section
Pressure Ratings:
·Flange Sizes up to ANSI 1,500; Raised Face Flanges Standard; Others Optional
Construction:
·316/316L Standard; Other Materials Available; Designed and Fabricated per ASME B31.3 & ASME IX; Full Material Certifications Optional
Certifications:
·Class 1, Div. 1, Groups C&D;
EEx d IIB T5 78oC - IP66 (Optional)
Process Connections:
·Low Range Analyzers: 1,2,3,4 inch Flanges and Insertion Type in 3" Flange
·All Other Analyzers: 2,3,4 inch Flanges and Insertion Type in 3" Flange
Cable:
·Dedicated 19 Conductor, 22 AWG, 3 Twisted Pairs, 1/2" Diameter, Special Factory installed Military Connector (armored cable not available). 150 feet Maximum Length between Electronics and Measurement
Water Cut Analyzer Measurement Section Dimensions:
Nominal Pipe Size Configuration "U", "Z", "L" or Insertion (Note 1) Flange
Size (Note 2) DimensionsNet Weight lbs.
A B C D
1 inch U & Z 150 39.7 5.1 13.3 2428
1 inch U & Z 300 39.7 5.4 13.3 2431
1 inch U & Z 600 39.7 5.7 13.3 2431
1 inch U & Z 900 39.7 6.3 13.3 2436
2 inch U & Z 150 41.8 6.0 14.8 2452
2 inch U & Z 300 41.8 6.3 14.8 2456
2 inch U & Z 600 41.8 6.6 14.8 2460
2 inch U & Z 900 41.8 8.0 14.8 2472
2 inch L 150 ---- 6.2 15 1036
2 inch L 300 ---- 6.5 15 1040
2 inch L 600 ---- 6.8 15 1044
2 inch L 900 ---- 8.0 15 1056
3 inch U & Z 150 44.0 7.3 16.2 2478
3 inch U & Z 300 43.3 7.6 16.2 2491
3 inch U & Z 600 43.3 8.0 16.2 2491
3 inch U & Z 900 43.3 8.8 16.2 24113
Nominal Pipe Size or Type Configuration "U", "Z", "L" or Insertion (Note 1 & 4) Flange Size (Note 2) DimensionsNet Weight lbs.
A B C D
3 inch L 150 ---- 7.25 16.2 1052
3 inch L 300 ---- 7.6 16.2 1060
3 inch L 600 ---- 8 16.2 1060
3 inch L 900 ---- 8.8 16.2 1082
Low
Range Insertion 150 6.1 5.8 25.8 ---- 26
Mid/Full/High
Range Insertion 150 6.1 10.5 25.8 ---- 37
Low
Range Insertion 600 6.1 5.8 30.5 ---- 28
Mid/Full/High
Range Insertion 600 6.1 10.5 30.5 ---- 39
4 inch U & Z 150 33.2 8.5 16.7 12120
4 inch U & Z 300 33.7 8.9 16.7 12140
4 inch U & Z 600 34.1 9.8 16.7 12150
4 inch U & Z 900 34.4 10.3 16.7 12178
4 inch L 150 ---- 8.5 16.1 1067
4 inch L 300 ---- 8.9 16.1 1087
4 inch L 600 ---- 9.75 16.1 10108
4 inch L 900 ---- 10.25 16.1 10136
Notes:
1. Consult Factory for configurations including High Temperature versions.
2. Flanges are dimensioned as ANSI Raised Face. Higher pressure rating flanges and RTJ flanges are available - consult Factory for dimensions and availability.
3.Mid Range, Full Range and High Range are not available in 1" pipe.
4. Insertion units have different lengths depending upon water cut measurement range. The Low Range has different dimensions from Mid, Full or High Range analyzers. All have 3" flanges.
|